Gripping Force Meters - Technical data |
![]() |
Technical Details
The SKM 1200 and SKM 1500 gripping force meters meet the EMV regulation 89/336/EWG and are marked with the CE-sign to indicate conformity with the relevant European safety standards. |
| SKM 1200 | SKM 1500 | ![]() |
|
| Measuring Range | 0 ... 200.0 kN | 0 ... 500.0 kN | |
| Lowest unit of measurement | 0.1 kN | ||
| Permitted overload | 100 ... 120 % of max. range value |
||
| Excess overload | > 120 % of max. range value |
||
| Display range | 0 ... 20,000 Digits | ||
| Measuring tolerance | < +/- 0.5 % of max. range value | ||
| Measuring frequency | 1,000 Hz | ||
| Display frequency | 4 Hz (average value from 250 readings) | ||
| Maximum value record | maximum value memory | ||
| Unit scales | t, kN, klbs | ||
| Number of jaws | 2, 3, 6 | ||
| Battery | rechargeable with main adapter 230 VAC / 50 Hz | ||
| Operating time | 10 hours from a full charge | ||
| Recharging time | 8 hours with unit switched off | ||
| Casing dimensions | 155 x 75 x 39 mm | ||
| Insulation | to IP 65 standards | ||
| Measuring head dimensions | 55 mm Ø | 104 mm Ø | |
| Chucking diameter | 63 ... 293 mm Ø | 114 ... 744 mm Ø | |
| Weight | approx. 1.3 kg | approx. 2.9 kg | |
| Number of jaws | 2, 3, 6 |
![]() |
Record maximum / overload |
| Gripping Force | 0-200 kN (SKM 1200) |
| 0-500 kN (SKM 1500) | |
| Battery | needs charging |
| Unit scale | t, kN, k lbs |
![]() |
Record maximum valueThe maximum value recorded is stored and displayed. Maximum value mode allows to take a reading in chucking situations when the display cannot be viewed. The maximum value remains displayed after unclamping the meter. The memory can be cleared before a new maximum value reading is taken by pressing the CLR button. If the memory isn't cleared manually it will be cleared automatically whenever the next reading is taken and the new result will be displayed. In order to avoid misinterpreted readings, the maximum recorded value is automatically deleted, whenever the meter is switched off. |
![]() |
Changing number of jawsThe number of jaws changes each time this key is pressed. The chosen number of jaws is shown in the top right corner of the display. Possible values are 2, 3 and 6 jaws. The reading eventually displayed is the actual measurement multiplied by the number of jaws selected, and the maximum value is cleared. |
![]() |
Clear maximum valueThe recorded maximum value is cleared, but the unit remains in maximum value mode. |
![]() |
Changing the unit scaleOn pressing this button the unit scale is changed. Available unit scales are t, kN and klbs. The value read is recalculated and displayed when the unit scale is changed. 1 kN = 1000N, 1 t = 9807 N, 1 klbs = 1000 lbs = 4448 N |
![]() |
Switching on / offCurrent settings remain stored when the meter is switched off. Upon switching it back on, measuring operations can be started immediately. |
![]() |
Adjusting the zero-pointThe zero-point on the meter is adjusted by pressing this button. This function should only be used when the meter is not clamped or loaded. |
Features ![]() |
Function / Usage ![]() |
Techncal Data | Accessories ![]() |